Related Experiment Video
Updated: Apr 26, 2026

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
3D dynamic pituitary MR imaging with CAIPIRINHA: initial experience and comparison with 2D dynamic MR imaging
Yasutaka Fushimi1, Tomohisa Okada1, Mitsunori Kanagaki1
1Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507, Japan.
Three-dimensional (3D) dynamic pituitary magnetic resonance imaging (MRI) using controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) significantly improves visualization of the posterior lobe and stalk compared to 2D dynamic MRI.
Area of Science:
- Radiology
- Medical Imaging
- Neuroimaging
Background:
- Pituitary and parasellar lesions require accurate imaging for diagnosis.
- Dynamic pituitary MRI is crucial for evaluating pituitary gland function and structure.
- Differentiating the posterior lobe and stalk is vital for assessing pituitary pathology.
Purpose of the Study:
- To assess the diagnostic accuracy of 3D dynamic pituitary MRI with CAIPIRINHA technique.
- To compare the visualization of the posterior pituitary lobe and stalk between 3D and 2D dynamic MRI sequences.
- To evaluate the quantitative enhancement characteristics of these structures using both imaging techniques.
Main Methods:
- 32 patients with pituitary or parasellar lesions underwent 3T 3D dynamic pituitary MRI with CAIPIRINHA.
- Imaging included precontrast and 5 dynamic contrast-enhanced series at 20-second intervals.
- Image analysis focused on the identification and normalized values of the posterior lobe and stalk, comparing 3D and 2D techniques.
Main Results:
- The posterior lobe was identified in 28/32 (87.5%) and the stalk in 29/32 (90.6%) with 3D MRI.
- In contrast, the posterior lobe was identified in only 15/32 (46.9%) and the stalk in 26/32 (81.3%) with 2D MRI.
- Normalized values for both the posterior lobe and stalk were significantly higher in 3D compared to 2D MRI (P<0.001).
Conclusions:
- 3D dynamic pituitary MRI with CAIPIRINHA offers superior identification of the pituitary posterior lobe and stalk compared to 2D dynamic MRI.
- This advanced technique provides higher normalized signal values, enhancing the delineation of these critical pituitary structures.
- 3D dynamic pituitary MRI is a valuable tool for improved assessment of pituitary gland abnormalities.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging