One-year mortality in patients requiring prolonged mechanical ventilation: multicenter evaluation of the ProVent
Introduction:
Current severity-of-illness indexes are unable to assess the long-term prognosis of patients requiring prolonged mechanical ventilation. A prognostic scoring system (Prognosis for Prolonged Ventilation score - ProVent - score) seems able to evaluate one-year mortality of such patients. However, testing of the model outside the developers' centers has not been reported. So, it is unclear how the ProVent score performs in non-US and non-tertiary ICUs. The goal of our study was to evaluate its performances in a French multicenter, community hospital-based setting.
Methods:
In three primary ICUs, 201 patients requiring mechanical ventilation for at least 21 days were enrolled in a retrospective cohort study. ICU mortality was abstracted from medical records and, for patients discharged alive from the ICU, one-year mortality was determined by telephone calls to patients' general practitioners.
Results:
One-year mortality was 60% (n = 120). On day 21 of ventilation, ProVent score value was 0 in 19 patients (9%), 1 in 63 patients (31%), 2 in 64 patients (32%), 3 in 37 patients (18%), and ≥4 in 18 patients (9%), respectively. For ProVent score values ranging from 0 to ≥4, one-year mortality rates were 21%, 43%, 67%, 78%, and 94%, respectively. The area under the curve (AUC) of the receiver operator characteristic (ROC) curve for the ProVent score was 0.74 (95% confidence interval 0.671 to 0.809). Stepwise logistic regression analysis showed that only three variables (age ≥65 years, vasopressors, and hemodialysis) were independently associated with one-year mortality in our population. In assigning one point to each variable, we created a French ProVent score. The Hosmer-Lemeshow goodness-of-fit statistic was 1.36 (DF = 6, P = 0.857) and the AUC of the ROC curve was 0.742 (95% confidence interval 0.673 to 0.810). One-year mortality rates for French ProVent score ranging from 0 to 3 were 34.6%, 70.9%, 83.3% and 100%, respectively (P <0.0001).
Conclusions:
The ProVent score is able, even in non-US ICUs and in community hospitals, to accurately identify among patients requiring prolonged mechanical ventilation those who are at high risk of one-year mortality. Its simplification appears possible. However, further validation of this French ProVent score in a larger external sample is indicated.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pneumonia III: Complications and Assessment
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...