William R Munday1, Zachary Klett, Jennifer M McNiff
1Yale-New Haven Hospital, Department of Pathology, New Haven, CT, USA.
Objective:
A foreign body giant cell (FBGC) reaction may occur in response to implanted xenogenic biomaterials. Here we report a FBGC reaction to the recently introduced xenogenic biomaterial, tarSys™, used for correction of lower eyelid retraction.
Method:
A retrospective chart review of two patients with FBGC reaction to tarSys™ implantation was performed.
Results:
Two patients (aged 51, 58 year) with lower eyelid retraction underwent surgical implantation of tarSys™ spacer grafts for correction. Both patients subsequently experienced chronic swelling requiring graft removal. Examination of the specimens showed a palisading FBGC reaction around acellular pink fibrillar material.
Conclusion:
A FBGC reaction may follow implantation of the tarSys™ xenograft.
More Related Videos
06:06Induction and Scoring of Graft-Versus-Host Disease in a Xenogeneic Murine Model and Quantification of Human T Cells in Mouse Tissues using Digital PCR
Published on: May 23, 2019
09:25An Immunological Model for Heterotopic Heart and Cardiac Muscle Cell Transplantation in Rats
Published on: May 8, 2020
Related Concept Videos
Cell-mediated Immune Responses
Tissue Transplantation
The Biology of Tissue Transplantation
The biology of tissue transplantation hinges on the Major Histocompatibility Complex (MHC) molecules. These molecules...
Hypersensitivity Reactions: Immune-Complex Reactions
Hypersensitivity Reactions: Delayed Hypersensitivity Reactions