The advantage of mixed-mode separation in the first dimension of comprehensive two-dimensional liquid-chromatography
Duxin Li1, Roman Dück2, Oliver J Schmitz1
1Applied Analytical Chemistry, Faculty of Chemistry, University of Duisburg-Essen, Universitaetsstr. 5-7, 45141 Essen, Germany; Institute of Pure and Applied Mass Spectrometry, University of Wuppertal, Gaussstr. 20, 42119 Wuppertal, Germany.
Abstract:
Comprehensive two-dimension liquid chromatography (LC×LC) has exhibited its powerful ability to separate complex samples. However, the use of a single chromatographic mode in 1st dimension has been limited to the separation of components by their individual characteristics, such as hydrophobicity, ionic properties etc. The use of mixed-mode stationary phases has revealed opportunities to combine different retention mechanisms. In this respect, stationary phases featuring both RP-like hydrophobic and ion-exchange interactive sites promise great versatility in retaining both polar and more apolar ionic and non-ionic compounds. We have therefore developed an LC×LC system based on mixed-mode (strong anion exchange and reversed phase) in the first dimension and a C18 phase in the second dimension. The system has been evaluated with standard compounds and applied for the separation of white wine and Chinese Herbal Medicine (CHM). The mixed-mode system SAX-PFP×C18 results in a better separation than a single mode system such as SAX×C18 or PFP×C18. Although little improvement in orthogonality (0.91 instead 0.86) is achieved with SAX×C18, the mixed-mode SAX-PFP×C18 gives a much larger effective peak distribution area in the analysis of e. g. white wine. But the analysis of aqueous extracts of CHM (Hdyotis diffusa and Scutellaria barbata) with SAX-PFP×RP leads to a very long analysis time because of strong hydrophobic interactions with the PFP column. Thus, the system was changed by using a cyano phase instead of a PFP phase. The improved SAX-CN×C18 system shows a better peak distribution and more importantly a reasonable analysis time.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Ion-Exchange Chromatography
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...