Related Experiment Video
Updated: Apr 26, 2026

Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
A novel method to measure sensory nerve conduction of the supraclavicular nerve
Shoji Hemmi1, Katsumi Kurokawa, Taiji Nagai
1Department of Neurology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama, 701-0192, Japan.
Introduction:
In this report we describe a reliable method for recording sensory nerve action potentials (SNAPs) of the supraclavicular nerve.
Methods:
Supraclavicular SNAPs were recorded by placing a surface active electrode at the posterior border of the sternocleidomastoid muscle at a distance of 6 cm from the sternoclavicular joint. The nerve was stimulated at the lower border of the clavicle 4.5 cm lateral to the sternoclavicular joint.
Results:
Supraclavicular SNAPs were recorded bilaterally from 20 healthy volunteers. Mean onset latency was 1.0 ± 0.2 ms, and mean peak latency was 1.4 ± 0.3 ms. Mean baseline-to-peak amplitude for the SNAPs was 6.1 ± 2.2 µV, and mean maximum conduction velocity was 59.8 ± 6.2 m/s. The mean percentage of side-to-side difference in amplitude was 12.9 ± 11.0%.
Conclusions:
Supraclavicular SNAPs could be obtained in all normal subjects. Assessment of supraclavicular nerve conduction is very useful in the diagnosis of supraclavicular neuropathy.