Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
C-THV measures of self-expandable valve positioning and correlation with implant outcomes
Pablo Codner1, Ifat Lavi, Guy Malki
1Interventional Cardiology Department, Beillinson Hospital, Rabin Medical Center and the "Sackler", Faculty of Medicine Tel-Aviv University, Israel.
Background:
Accurate positioning of the valve device during transcutaneous aortic valve implantation (TAVI) is of crucial importance. The Paieon C-THV navigation system has been designed to correctly guide device deployment during TAVI.
Objectives:
Using this navigation system we aimed to determine the correlation between the anatomic measures of the native aortic valve and the deployed self-expandable valve positioning and to explore the impact upon procedural outcomes.
Methods:
We analyzed data of 68 patients with severe symptomatic aortic stenosis undergoing TAVI, using the catheter-based Medtronic-CoreValve self-expandable system. Patients were subdivided into two groups according to whether the C-THV system was used (50) or not (18) during the implantation process. Analysis of geometrical outcomes vs. clinical outcomes including postprocedural electrical conduction defect and/or para-valvular leaks was performed.
Results:
Taking the target implantation line as a reference; relatively lower vs. higher implantations correlated with a higher frequency of any new onset electrical conduction defect (ECD). The mean corresponding distance from valve inferior edge below the virtual aortic annulus line was 3.0 ± 1.6 mm vs. 1.2 ± 1.3 mm in patients with (38.5%) vs. without any new onset ECD, respectively (P = 0.05). The use of C-THV navigation seemed to correlate with higher valve implants but it had no impact on the occurrence of postprocedural paravalvular leaks.
Conclusions:
Self-expandable valve implants guided by C-THV navigation seems to be associated with more precise implants and lower risk for postprocedural electrical conduction defects, due to higher location in relation to the target line.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Related Concept Videos
Mitral Stenosis IV: Nursing Management
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...