Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

7.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.6K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

887
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
887
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.0K
Region of Convergence of Laplace Tarnsform01:20

Region of Convergence of Laplace Tarnsform

1.4K
The Region of Convergence (ROC) is a fundamental concept in signal processing and system analysis, particularly associated with the Laplace transform. The ROC represents an area in the complex plane where the Laplace transform of a given signal converges, determining the transform's applicability and utility.
Consider a decaying exponential signal that begins at a specific time. When deriving its Laplace transform, the time-domain variable is replaced with a complex variable. This...
1.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Long-term chest CT abnormalities up to 4.5 years after COVID-19 hospitalization and their association with dyspnea and fatigue: a prospective cohort study.

Respiratory research·2026
Same author

Towards sustainable implementation of robotic surgery: an interregional strategic framework from Norway.

Journal of robotic surgery·2026
Same author

Fast scanning in chest CT: Investigating clinical and technical image quality features.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same author

Annotation and characterization of lesions in breast tomosynthesis images.

Radiation protection dosimetry·2026
Same author

Specialist medical physicist in Sweden-implementation of a higher professional level raising the bar for patient safety and clinical precision for meeting future challenges in therapy and diagnostics.

Radiation protection dosimetry·2026
Same author

"I Want to Spend My Time Living"-Experiences With a Digital Outpatient Service With a Mobile App for Tailored Care Among Adults With Long-Term Health Service Needs: Qualitative Study Using Thematic Analysis.

Journal of medical Internet research·2026

Related Experiment Video

Updated: Apr 26, 2026

Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
08:39

Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects

Published on: June 24, 2025

718

Comparing five different iterative reconstruction algorithms for computed tomography in an ROC study.

Kristin Jensen1, Anne Catrine T Martinsen, Anders Tingberg

  • 1The Intervention Centre, Rikshospitalet, Postboks 4950, Nydalen, 0424, Oslo, Norway, uxjekr@ous-hf.no.

European Radiology
|July 23, 2014
PubMed
Summary
This summary is machine-generated.

Iterative reconstruction CT algorithms vary in effectiveness for lesion detection. While all reduce noise, only two of five tested algorithms significantly improved lesion conspicuity compared to filtered back projection.

More Related Videos

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

42.6K
Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.7K

Related Experiment Videos

Last Updated: Apr 26, 2026

Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
08:39

Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects

Published on: June 24, 2025

718
Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

42.6K
Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.7K

Area of Science:

  • Radiology
  • Medical Imaging
  • Image Reconstruction

Background:

  • Filtered back projection (FBP) is a standard CT image reconstruction method.
  • Iterative reconstruction (IR) techniques offer potential improvements in image quality and radiation dose reduction.
  • Evaluating the performance of different IR algorithms across vendors and dose levels is crucial for clinical application.

Purpose of the Study:

  • To compare the lesion conspicuity achieved by five different iterative reconstruction techniques from four CT vendors.
  • To assess the impact of three different radiation dose levels on lesion detection.
  • To compare iterative algorithms against filtered back projection (FBP).

Main Methods:

  • An anthropomorphic liver phantom was scanned using four CT systems from different vendors.
  • Images were reconstructed using FBP and iterative algorithms at CTDIvol levels of 5, 10, and 15 mGy.
  • Four independent observers evaluated images, calculating areas under the ROC curve (AUCs), noise levels, and contrast-to-noise ratios (CNR).

Main Results:

  • One iterative algorithm significantly increased AUC compared to FBP across all dose levels (p < 0.001).
  • Another algorithm improved AUC at 5 mGy (p = 0.007), but not at higher doses.
  • Three iterative algorithms showed no significant difference in AUC compared to FBP, despite all algorithms reducing noise (10-71%) and improving CNR.

Conclusions:

  • Only two of the five evaluated iterative reconstruction algorithms demonstrated improved lesion detection compared to FBP.
  • Iterative reconstruction algorithms have varying effects on lesion detectability, influenced by dose levels.
  • While all tested algorithms reduced image noise and improved CNR, improved lesion detection was algorithm-specific.