Early detection of fetal cardiac abnormalities: how effective is it and how should we manage these patients?
Sally-Ann B Clur1, Caterina M Bilardo
1Department of Pediatric Cardiology of the Emma Children's Hospital, Academic Medical Centre, Amsterdam, The Netherlands; The Centre for Congenital Heart Anomalies Amsterdam-Leiden (CAHAL), Amsterdam, The Netherlands.
Insights
Early detection of congenital heart defects (CHDs) is possible using first-trimester screening and early fetal echocardiography (EFEC). Specific markers can identify high-risk fetuses for EFEC, improving diagnostic accuracy.
Area of Science:
- Medical imaging
- Prenatal diagnostics
- Cardiology
Background:
- Congenital heart defects (CHDs) are common congenital malformations leading to significant mortality and morbidity.
- Advancements in ultrasound technology and recognition of early markers have increased interest in first-trimester CHD screening.
- Early fetal echocardiography (EFEC) is feasible before 16 weeks' gestation with adequate expertise.
Purpose of the Study:
- To review the detection of major CHDs in the first and early second trimesters.
- To identify specific markers for high-risk groups amenable to EFEC.
- To assess the diagnostic accuracy and utility of EFEC.
Main Methods:
- Review of first-trimester screening for major CHDs.
- Identification of markers such as increased nuchal translucency, abnormal ductus venosus flow, and tricuspid regurgitation.
- Evaluation of EFEC sensitivity and concordance with mid-gestational echocardiograms in high-risk populations.
Main Results:
- First-trimester CHD detection rates vary (2.3-56%) based on experience and population.
- Increased nuchal translucency, abnormal ductus venosus flow, and tricuspid regurgitation are associated with increased CHD risk.
- EFEC shows 78.5% sensitivity and 74.5% concordance with later scans in high-risk groups.
Conclusions:
- EFEC can identify high-risk fetuses for congenital heart defects using specific first-trimester markers.
- Skilled personnel and diagnostic accuracy are crucial for implementing EFEC in management protocols.
- Limitations of EFEC necessitate a later confirmatory echocardiogram.
Abstract:
Congenital heart defects (CHDs), the most commonly occurring congenital malformations, cause significant mortality and morbidity. With the recognition of early markers for CHD and the development of better ultrasound resolution, interest has turned toward performing a screening anomaly scan, including the heart, together with the nuchal scan. It is also possible, with adequate skill and training, to competently perform an echocardiogram <16 weeks' gestation. This article reviews the detection of major CHD in the first trimester and early second trimester including specific markers that help to identify high-risk groups for early fetal echocardiography (EFEC). CHD detection during first-trimester screening is low (2.3-56%) depending on the center's experience and the population studied. An increased nuchal translucency, abnormal ductus venosus flow, and tricuspid regurgitation in the first trimester are associated with an increased CHD risk and can be used together to identify high-risk fetuses for EFEC. EFEC requires skilled scanning and the expertise of a fetal echocardiographer. In high-risk populations, it is 78.5% sensitive with a 74.5% concordance between the EFEC and the mid-gestational echocardiogram. The availability of qualified personnel and diagnostic accuracy are prerequisites before EFEC can be introduced into management protocols. The limitations of EFEC should be recognized, and a later confirmatory echocardiogram is recommended.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Mitral Valve Prolapse II: Assessment and Management
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias VII: Nursing Management of Dysrhythmias
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...