Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

887
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
887
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

847
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
847
Computed Tomography01:10

Computed Tomography

7.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.6K
Positron Emission Tomography01:29

Positron Emission Tomography

6.2K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
6.2K
Brain Imaging01:14

Brain Imaging

1.0K
Brain imaging technologies provide critical insights into both the structure and function of the human brain, enabling medical professionals and researchers to diagnose, study, and treat neurological disorders or psychiatric disorders more effectively.
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans),  magnetic resonance imaging (MRI),  functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
1.0K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

419
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
419

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Kinase-Glo luminescent kinase assay for in vitro determination of PKA activity].

Xi bao yu fen zi mian yi xue za zhi = Chinese journal of cellular and molecular immunology·2012
Same author

Functional characterization of an arrestin gene on insecticide resistance of Culex pipiens pallens.

Parasites & vectors·2012
Same author

MiR-23a inhibits myogenic differentiation through down regulation of fast myosin heavy chain isoforms.

Experimental cell research·2012
Same author

Let-7b inhibits human cancer phenotype by targeting cytochrome P450 epoxygenase 2J2.

PloS one·2012
Same author

Role of IKK/NF-κB signaling in extinction of conditioned place aversion memory in rats.

PloS one·2012
Same author

Inhibition of poly(ADP-ribose) polymerase attenuates acute kidney injury in sodium taurocholate-induced acute pancreatitis in rats.

Pancreas·2012

Related Experiment Video

Updated: Apr 26, 2026

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging
17:06

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging

Published on: November 8, 2012

26.0K

Diffuse optical tomography enhanced by clustered sparsity for functional brain imaging.

Chen Chen, Fenghua Tian, Hanli Liu

    IEEE Transactions on Medical Imaging
    |July 24, 2014
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces a new clustered sparsity reconstruction (CSR) algorithm for diffuse optical tomography (DOT). The CSR method enhances brain function imaging by accurately reconstructing clustered absorption changes, outperforming existing techniques.

    More Related Videos

    Simultaneous Data Collection of fMRI and fNIRS Measurements Using a Whole-Head Optode Array and Short-Distance Channels
    08:19

    Simultaneous Data Collection of fMRI and fNIRS Measurements Using a Whole-Head Optode Array and Short-Distance Channels

    Published on: October 20, 2023

    2.0K
    Cerebral Blood Flow-Based Resting State Functional Connectivity of the Human Brain using Optical Diffuse Correlation Spectroscopy
    07:13

    Cerebral Blood Flow-Based Resting State Functional Connectivity of the Human Brain using Optical Diffuse Correlation Spectroscopy

    Published on: May 27, 2020

    6.3K

    Related Experiment Videos

    Last Updated: Apr 26, 2026

    Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging
    17:06

    Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging

    Published on: November 8, 2012

    26.0K
    Simultaneous Data Collection of fMRI and fNIRS Measurements Using a Whole-Head Optode Array and Short-Distance Channels
    08:19

    Simultaneous Data Collection of fMRI and fNIRS Measurements Using a Whole-Head Optode Array and Short-Distance Channels

    Published on: October 20, 2023

    2.0K
    Cerebral Blood Flow-Based Resting State Functional Connectivity of the Human Brain using Optical Diffuse Correlation Spectroscopy
    07:13

    Cerebral Blood Flow-Based Resting State Functional Connectivity of the Human Brain using Optical Diffuse Correlation Spectroscopy

    Published on: May 27, 2020

    6.3K

    Area of Science:

    • Biomedical Optics
    • Neuroimaging
    • Medical Physics

    Background:

    • Diffuse optical tomography (DOT) noninvasively measures hemodynamic changes using near-infrared light for brain function studies.
    • DOT reconstruction is ill-posed due to light propagation complexities.
    • Sparsity regularization shows promise over Tikhonov regularization for DOT.

    Purpose of the Study:

    • To develop a novel algorithm for clustered sparsity reconstruction (CSR) in DOT.
    • To leverage the structured nature of functional brain activity for improved image reconstruction.
    • To enhance the accuracy of reconstructing in vivo absorption changes during brain function.

    Main Methods:

    • Exploitation of structured sparsity in diffuse optical images.
    • Development of a clustered sparsity reconstruction (CSR) algorithm.
    • Validation through numerical simulations, phantom experiments, and human in vivo measurements.

    Main Results:

    • The proposed CSR algorithm demonstrated superior performance compared to state-of-the-art methods.
    • Numerical simulations and phantom experiments confirmed the effectiveness of CSR.
    • Human in vivo measurements validated the advantages of the CSR method for brain imaging.

    Conclusions:

    • The CSR algorithm offers enhanced accuracy for DOT image reconstruction.
    • This method effectively utilizes the clustered nature of functional brain activation.