Interobserver agreement in the interpretation of outpatient head CT scans in an academic neuroradiology practice
G Guérin1, S Jamali2, C A Soto1
1From the Department of Radiology (G.G., C.A.S., F.G., J.R.), Centre Hospitalier de l'Université de Montréal, Notre-Dame Hospital, Montreal, Quebec, Canada.
Background And Purpose:
The repeatability of head CT interpretations may be studied in different contexts: in peer-review quality assurance interventions or in interobserver agreement studies. We assessed the agreement between double-blind reports of outpatient CT scans in a routine academic practice.
Materials And Methods:
Outpatient head CT scans (119 patients) were randomly selected to be read twice in a blinded fashion by 8 neuroradiologists practicing in an academic institution during 1 year. Nonstandardized reports were analyzed to extract 4 items (answer to the clinical question, major findings, incidental findings, recommendations for further investigations) from each report, to identify agreement or discrepancies (classified as class 2 [mentioned or not mentioned or contradictions between reports], class 1 [mentioned in both reports but diverging in location or severity], 0 [concordant], or not applicable), according to a standardized data-extraction form. Agreement regarding the presence or absence of clinically significant or incidental findings was studied with κ statistics.
Results:
The interobserver agreement regarding head CT studies with positive and negative results for clinically pertinent findings was 0.86 (0.77-0.95), but concordance was only 75.6% (67.2%-82.5%). Class 2 discrepancy was found in 15.1%; class 1 discrepancy, in 9.2% of cases. The κ value for reporting incidental findings was 0.59 (0.45-0.74), with class 2 discrepancy in 29.4% of cases. Most discrepancies did not impact the clinical management of patients.
Conclusions:
Discrepancies in double-blind interpretations of head CT examinations were more common than reported in peer-review quality assurance programs.
More Related Videos
14:08Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
12:50Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...