Evaluation and control of waste anesthetic gases in the postanesthesia care unit
Background:
Few studies have addressed waste anesthetic gases (WAGs) in the postanesthesia care unit (PACU) related to exhaled sevoflurane and nitrous oxide.
Purpose:
To evaluate the effectiveness of a new scavenging system to control WAGs in the PACU.
Design:
Comparative and descriptive study.
Methods:
This pilot study compared exposure to WAGs with and without a scavenging system using infrared technology to visualize and quantify exposure to these gases in the PACU.
Finding:
The results showed a significant reduction (P < .05) in both nitrous oxide and sevoflurane at both six inches and three feet from the patient's breathing zone, as well as in the work area of the perianesthesia nurses in the PACU.
Conclusions:
WAG exposure may be more easily managed through the use of this new scavenging system to better control occupational exposures to these gases among PACU personnel.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Aneurysm IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Suctioning the Nasopharyngeal Airway
Equipment Required
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....