High-throughput viscosity measurement using capillary electrophoresis instrumentation and its application to protein
Andrea Allmendinger1, Le-Ha Dieu2, Stefan Fischer3
1Late Stage Pharmaceutical and Processing Development, Pharmaceutical Development & Supplies, Pharma Technical Development Biologics EU, F. Hoffmann-La Roche Ltd, Grenzacherstrasse 124, 4070 Basel, Switzerland; Division of Pharmaceutical Technology, Department of Pharmaceutical Sciences, University of Basel, Klingelbergstrasse 50, 4056 Basel, Switzerland.
Abstract:
Viscosity characterization of protein formulations is of utmost importance for the development of subcutaneously administered formulations. However, viscosity determinations are time-consuming and require large sample volumes in the range of hundreds of microliters to a few milliliters, depending on the method used. In this article, an automated, high-throughput method is described to determine dynamic viscosity of Newtonian fluids using standard capillary electrophoresis (CE) equipment. CE is an analytical method routinely used for the separation and characterization of proteins. In our set-up, the capillary is filled with the test sample, and a constant pressure is applied. A small aliquot of riboflavin is subsequently loaded into the capillary and used as a dye to monitor movement of protein samples. Migration time of the riboflavin peak moving through the filled capillary is converted to the viscosity by applying the Hagen-Poiseuille's law. The instrument is operated without using an electrical field. Repeatability, robustness, linearity, and reproducibility were demonstrated for different capillary lots and instruments, as well as for different capillary lengths and diameters. Accuracy was verified by comparing the viscosity data obtained by CE instrumentation with those obtained by plate/cone rheometry. The suitability of the method for protein formulations was demonstrated, and limitations were discussed. Typical viscosities in the range of 5-40mPas were reliably measured with this method. Advantages of the CE instrumentation-based method included short measurement times (1-15min), small sample volumes (few microliters) for a capillary with a diameter of 50μm and a length of 20.5cm as well as potential to be suitable for high-throughput measurements.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...