Related Experiment Video
Updated: Apr 26, 2026

Detection of Glycosaminoglycans by Polyacrylamide Gel Electrophoresis and Silver Staining
Published on: February 25, 2021
Possibility of analytical finding of glycerol caused by self-catheterization in doping control
Masato Okano1, Yasunori Nishitani, Shinji Kageyama
1Anti-Doping Laboratory, LSI Medience Corporation, Tokyo, Japan.
Abstract:
Glycerol is listed on the World Anti-Doping Agency (WADA) prohibited list as a masking agent principally because the administration of glycerol increases plasma volume and decreases the concentration of haemoglobin and the value of haematocrit in blood. Glycerol is a naturally occurring substance; therefore, the threshold is set as 1.0 mg/mL in the WADA technical document (WADA TD2013DL). In a WADA-accredited doping control laboratory, three doping control urine specimens collected from impaired athletes were determined to contain a high concentration of glycerol (>1.0 mg/mL); two of these specimens were considered adverse analytical findings (AAFs). Self-catheterization is necessary for athletes with neurological disorders such as neurogenic bladder dysfunction. We conducted a simple simulation of self-catheterization as an experimental test using urethral catheters with an antiseptic agent containing glycerol to confirm the influence of this antiseptic agent on the quantitative value of glycerol in doping control analysis. Some users employ a catheter with glycerol solution (ca. 1 mL) to avoid pain during use. The urine sample passed through such a catheter exhibited a glycerol concentration (4.94 mg/mL) greater than the threshold level. In September 2014, the threshold for glycerol will change from 1.0 to 4.3 mg/mL (WADA TD2014DL); however, a possibility exists for the quantitative value of glycerol in doping control analysis to exceed the threshold because of the use of an antiseptic agent containing glycerol for self-catheterization. The AAF for glycerol for impaired athletes, particularly those who participate in Paralympic sports, should account for the use of a catheter with glycerol.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...

