Electrophysiologic assessment of low-frequency hearing: sedation effects
C W Palaskas1, M J Wilson, R A Dobie
1Department of Otolaryngology-Head and Neck Surgery, University of Washington, Seattle 98195.
Abstract:
Sixteen normal-hearing adults were tested in both awake and sedated states for several evoked responses to low-frequency stimuli. Responses obtained by cross-correlation function, middle latency responses, and the 40-Hz response proved most sensitive; all had mean thresholds of less than 20 dB normal hearing level for the awake-alert state, but 40-Hz and middle latency response mean thresholds were shifted about 10 dB under sedation. The cross-correlation method seems to offer promise for pediatric auditory assessment.