Evaluation of efficacy of a pulse oximeter to assess pulp vitality
Mohammed Sadique1, S V Ravi1, Kunjamma Thomas1
1Conservative Dentistry and Endodontics, Kunhitharuvai Memorial Charitable Trust Dental College, Manassery, Calicut, Kerala, India.
Background:
To evaluate the efficacy of pulse oximeter as a pulp vitality tester.
Materials And Methods:
The sample group consisted of 60 patients of age 15 to 30 years with normal maxillary anterior teeth. Thirty nonvital teeth with complete endodontic fillings were tested as control group. Systemic oxygen saturation values from the patient's fingers served as the control sample for comparison of pulp oxygen saturation values. Readings were recorded on index fingers first; teeth were then evaluated by placing sensor onto the tooth.
Results:
Nonvital teeth recorded oxygen saturation values of 0%. The mean value for central incisor was 85.11 (SD ± 2.07), for lateral incisors 80.21 (SD ± 2.03) and for canines 89.55 (SD ± 1.09). Their control values (patient's index fingers) averaged 95.88% (SD ± 0.66). Pearson's correlation analysis showed a correlation of 0.11 for central incisors, 0.19 for lateral incisors and 0.12 for canines.
Conclusion:
This study confirms that pulse oximeter is effective equipment for pulp vitality testing. Pulse oximeter evidences the actual method of evaluating the pulp vitality compared to contemporary methods. How to cite the article: Sadique M, Ravi SV, Thomas K, Dhanapal P, Simon EP, Shaheen M. Evaluation of efficacy of a pulse oximeter to assess pulp vitality. J Int Oral Health 2014;6(3):70-2.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...