Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

9.4K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
9.4K
X-ray Imaging01:24

X-ray Imaging

7.7K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
7.7K
Positron Emission Tomography01:29

Positron Emission Tomography

6.2K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
6.2K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.0K
X-ray Diffraction of Biological Samples01:10

X-ray Diffraction of Biological Samples

3.8K
X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are  scattered by the electron clouds around the sample atoms. The  X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
3.8K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

847
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
847

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Peri-implant squamous cell carcinoma.

Australian dental journal·2017
Same author

Sympathetic hyper-excitation in obesity and pulmonary hypertension: physiological relevance to the 'obesity paradox'.

International journal of obesity (2005)·2016
Same author

GENERALISATION OF RADIATOR DESIGN TECHNIQUES FOR PERSONAL NEUTRON DOSEMETERS BY UNFOLDING METHOD.

Radiation protection dosimetry·2015
Same author

Applicability of human dental follicle cells to bone regeneration without dexamethasone: an in vivo pilot study.

International journal of oral and maxillofacial surgery·2014
Same author

Recognition of deficient nutrient intake in the brain of rat withL-lysine deficiency monitored by functional magnetic resonance imaging, electrophysiologically and behaviorally.

Amino acids·2013
Same author

X-ray intravital microscopy for functional imaging in rat hearts using synchrotron radiation coronary microangiography.

The Review of scientific instruments·2013

Related Experiment Video

Updated: Apr 26, 2026

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

9.0K

Phase contrast portal imaging using synchrotron radiation.

K Umetani1, T Kondoh2

  • 1Japan Synchrotron Radiation Research Institute, SPring-8, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan.

The Review of Scientific Instruments
|August 3, 2014
PubMed
Summary

Synchrotron radiation phase contrast imaging enhances targeting accuracy for microbeam radiation therapy. This technique provides clearer images of bone structures for precise positioning of brain lesions in small animal models.

More Related Videos

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
08:46

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

Published on: April 13, 2016

9.6K
Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
08:51

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography

Published on: May 27, 2008

12.4K

Related Experiment Videos

Last Updated: Apr 26, 2026

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

9.0K
Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
08:46

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

Published on: April 13, 2016

9.6K
Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
08:51

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography

Published on: May 27, 2008

12.4K

Area of Science:

  • Medical physics
  • Radiotherapy research
  • Biomedical imaging

Background:

  • Microbeam radiation therapy (MRT) is an experimental cancer treatment with significant therapeutic potential.
  • Accurate targeting is crucial for MRT to maximize efficacy and minimize damage to healthy tissues.
  • Conventional portal imaging methods can lack sufficient contrast for precise anatomical localization.

Purpose of the Study:

  • To enhance targeting accuracy in microbeam radiation therapy (MRT) using synchrotron radiation phase contrast imaging.
  • To evaluate the effectiveness of propagation-based phase contrast imaging for portal imaging in small animal studies.
  • To improve the visualization of bony structures for lesion localization in preclinical MRT research.

Main Methods:

  • Application of a synchrotron radiation phase contrast technique to portal imaging.
  • Utilizing an X-ray imaging detector positioned 6.0 m downstream from the object for enhanced edge effects.
  • Acquisition of images from a mouse head sample using therapeutic white synchrotron radiation (130 keV mean energy).

Main Results:

  • Propagation-based phase contrast imaging produced a high-contrast edge enhancement effect.
  • Remarkably clear images of bones surrounding the cerebrum were acquired in an air environment.
  • The enhanced images allowed for precise positioning of brain lesions relative to skull structures, without overlapping surface structure confusion.

Conclusions:

  • Synchrotron radiation phase contrast imaging significantly improves image quality for MRT portal imaging.
  • This technique offers superior visualization of anatomical details compared to conventional methods.
  • The findings support the potential of phase contrast imaging for enhancing precision in preclinical MRT applications, particularly for brain lesion targeting.