[Evaluation of the hypomagnetic environment effects on capillary blood circulation, blood pressure and heart rate]
Abstract:
Impact of attenuated magnetic field (MF) on human health is a hard-core issue of present-day cosmonautics. A series of experiments with animals exposed in attenuated MF revealed violent disorders in cardiovascular system development. Purpose of the work was to study effects of the hypomagnetic environment (HME) on capillary blood circulation, blood pressure (BP) and heart rate (HR) in normal people. Participants (n = 34) were 24 men and 10 women free from cardiovascular symptoms. Mean age was 43.3 +/- 15.4 years. Thirteen participants, i.e. 8 men and 5 women, were randomly selected for a repeated investigation in the usual conditions (imaginary exposure); mean age in the group made up 47.9 +/- 18 years. Cardiac rhythm and heart rate were recorded using cardiac monitor Astrocard (Russia). BP was measured with the help of automatic blood pressure monitor Tonocard (Russia). Capillary circulation was determined using a digital capillaroscope (Russia) with high-speed CMOS-camera (100 frames/s). Time of HME exposure was 60 min. It was demonstrated that in healthy people free from cardiovascular symptoms HME increases capillary circulation rate by 22.4% as compared with records made under the usual conditions. There was a reliable HR reduction by the end of HME exposure with reference to the measurements taken at the onset. At the end of exposure, diastolic BP dropped considerably relative to mid-exposure values and systolic BP, on the contrary, made a significant rise.
More Related Videos
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Factors affecting Blood pressure
Physiological Factors: