Related Experiment Video
Updated: Apr 26, 2026

On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Analysis of siloxanes in hydrocarbon mixtures using comprehensive two-dimensional gas chromatography
Abhijit Ghosh1, Stacy K Seeley2, Steven R Nartker2
1Oakland University, Department of Chemistry, Rochester, MI 48309, United States.
Abstract:
A comprehensive two-dimensional gas chromatography (GC×GC) method for separating siloxanes from hydrocarbons has been developed using a systematic process. First, the retention indices of a set of siloxanes and a set of hydrocarbons were determined on 6 different stationary phases. The retention indices were then used to model GC×GC separation on 15 different stationary phase pairs. The SPB-Octyl×DB-1 pair was predicted to provide the best separation of the siloxanes from the hydrocarbons. The efficacy of this stationary phase pair was experimentally tested by performing a GC×GC analysis of gasoline spiked with siloxanes and by analyzing biogas obtained from a local wastewater treatment facility. The model predictions agreed well with the experimental results. The SPB-Octyl×DB-1 stationary phase pair constrained the hydrocarbons to a narrow range of secondary retention times and fully isolated the siloxanes from the hydrocarbon band. The resulting GC×GC method allows siloxanes to be resolved from complex mixtures of hydrocarbons without requiring the use of a selective detector.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...