Related Experiment Video
Updated: Apr 26, 2026

A Rapid and Specific Microplate Assay for the Determination of Intra- and Extracellular Ascorbate in Cultured Cells
Published on: April 11, 2014
Development and characterization of an ascorbate oxidase-based sensor-biosensor system for telemetric detection of AA
Antonio Barberis1, Ylenia Spissu, Gianfranco Bazzu
1Institute of Sciences of Food Production (ISPA), National Research Council (CNR) Italy , Traversa La Crucca, 3 Regione Baldinca, 07100 Li Punti, Sassari, Italy.
Abstract:
A new carbon ascorbate oxidase-based sensor-biosensor system (SB) was coupled to a dual-channel telemetric device for online simultaneous electrochemical detection of ascorbic acid (AA) and antioxidant capacity in Hamlin, Sanguinello, and Moro orange varieties. The electrocatalytic performances of the SB were investigated by cyclic voltammetry and amperometric techniques. The phenol composition of orange juice of each variety, and the cyclic voltammetries of the most represented phenols, were provided. The in vitro calibrations were performed in PBS (pH 5.6), applying a constant potential of +500 mV. A standard mixture of phenols, based on orange juice composition, was used as reference material for studying SB behavior. SB works at an applied potential of +500 mV, in a concentration range comprised between the LOD 0.26 μM and 20 μM. In this concentration range, limiting the data acquisition time to 2 min, the problems of electrode passivation due to phenols polymerization were overcome. AA calibration showed that the biosensor registered statistically lower currents than the sensor since the enzyme oxidized AA before it reached the electrode surface. Standard mixture calibration showed that currents registered by sensor and biosensor did not statistically differ. The difference between sensor and biosensor AA registered currents was used to calculate an AA selectivity index and, consequently, to determine the AA content and the antioxidant capacity in the juices. The novelty of the SB is its ability to distinguish between AA and phenols contribution to antioxidant capacity. The obtained results were in accordance with reference methods.
More Related Videos
09:33Imaging Approaches to Assessments of Toxicological Oxidative Stress Using Genetically-encoded Fluorogenic Sensors
Published on: February 7, 2018
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Microbial Biosensors
Amperometry: Overview
Redox Titration: Overview