Related Experiment Video
Updated: Apr 26, 2026

Targeted DNA Methylation Analysis by Next-generation Sequencing
Published on: February 24, 2015
Cytosine deamination is a major cause of baseline noise in next-generation sequencing
Guoli Chen1, Stacy Mosier, Christopher D Gocke
1Department of Pathology, The Sol Goldman Pancreatic Cancer Research Center, Johns Hopkins University School of Medicine, Suite 344, CRB-II, 1550 Orleans Street, Baltimore, MD, 21231, USA.
Background And Objectives:
As next-generation sequencing (NGS) becomes a major sequencing platform in clinical diagnostic laboratories, it is critical to identify artifacts that constitute baseline noise and may interfere with detection of low-level gene mutations. This is especially critical for applications requiring ultrasensitive detection, such as molecular relapse of solid tumors and early detection of cancer. We recently observed a ~10-fold higher frequency of C:G > T:A mutations than the background noise level in both wild-type peripheral blood and formalin-fixed paraffin-embedded samples. We hypothesized that these might represent cytosine deamination events, which have been seen using other platforms.
Methods:
To test this hypothesis, we pretreated samples with uracil N-glycosylase (UNG). Additionally, to test whether some of the cytosine deamination might be a laboratory artifact, we simulated the heat associated with polymerase chain reaction thermocycling by subjecting samples to thermocycling in the absence of polymerase. To test the safety of universal UNG pretreatment, we tested known positive samples treated with UNG.
Results:
UNG pretreatment significantly reduced the frequencies of these mutations, consistent with a biologic source of cytosine deamination. The simulated thermocycling-heated samples demonstrated significantly increased frequencies of C:G > T:A mutations without other baseline base substitutions being affected. Samples with known mutations demonstrated no decrease in our ability to detect these after treatment with UNG.
Conclusion:
Baseline noise during NGS is mostly due to cytosine deamination, the source of which is likely to be both biologic and an artifact of thermocycling, and it can be reduced by UNG pretreatment.
Related Concept Videos
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features....
Sanger Sequencing
Maxam-Gilbert Sequencing
Challenges of the Maxam-Gilbert Method
The...
RNA-seq
Before the discovery of RNA-seq, microarray-based methods and Sanger sequencing were used for transcriptome analysis. However, while...
Proofreading

