Related Experiment Video
Updated: Apr 26, 2026

Training Rats to Voluntarily Dive Underwater: Investigations of the Mammalian Diving Response
Published on: November 12, 2014
Partial dereverberation used to characterize open circuit scuba diver signatures
Kay L Gemba1, Eva-Marie Nosal1, Todd R Reed2
1Department of Ocean and Resources Engineering, School of Ocean and Earth Science and Technology, University of Hawai'i at Mānoa, Honolulu, Hawaii 96822.
Abstract:
The use of passive acoustics to detect self-contained underwater breathing apparatus (SCUBA) divers is useful for nearshore and port security applications. While the performance of a detector can be optimized by understanding the signal's spectral characteristics, anechoic recording environments are generally not available or are cost prohibitive. A practical solution is to obtain the source spectra by equalizing the recording with the inverse of the channel's impulse response. This paper presents a dereverberation method for signal characterization that is subsequently applied to four recorded SCUBA configurations. The inverse impulse response is computed in the least-square sense, and partial dereverberation of SCUBA is performed over the 6-18 kHz band. Results indicate that early reflections and late reverberation added as much as 6.8 dB of energy. Mean unadjusted sound pressure levels computed over the 0.3-80 kHz band were 130 ± 5.9 dB re 1 μPa at 1 m. Bubble noise carries a significant amount of the total energy and masks the regulator signatures from 1.3 to 6 kHz, depending on the regulator configuration. While the dereverberation method is applied here to SCUBA signals, it is generally applicable to other sources if the impulse response of the recording environment can be obtained separately.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:

