Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Uterine artery pulsatility index assessment at 11-13 weeks' gestation
Gus Ridding1, Philip J Schluter, Jon A Hyett
1Maternal Fetal Medicine Unit, Royal North Shore Hospital, Sydney, N.S.W., Australia.
Introduction:
First-trimester uterine artery pulsatility index (PI) measurements form part of an algorithm used to assess the risk of developing pre-eclampsia. The objective of this study was to construct a population-specific reference range for both the lower and mean maternal uterine artery PI at 11-13(+6) weeks' gestation and to assess measurement agreement.
Materials And Methods:
Reference ranges for mean and lower PI measurements were developed using polynomial regression models following prospective collection of maternal uterine artery PI measurements at 11-13(+6) weeks' gestation. Measurement agreement studies were performed by two experienced operators.
Results:
Measurements from 298 women were included in the primary study. Polynomial regression indicated no change over gestational age for the lower PI (mean 1.44). There was an inverse relationship between the average PI and gestational age (mean [0.8960 + (2.9771 × CRL(-1/2))]2). PI measurement agreement was good-strong (intraclass correlation (ICC) 0.50-0.79) between operators, and within-operator agreement was almost perfect (ICC 0.88-0.93).
Conclusions:
Reference ranges for both the average and lowest PI of the maternal uterine arteries were derived at 11-13(+6) weeks' gestation. This will provide a basis for development of auditable standards for first-trimester uterine artery Doppler measurements. The PI measurements are reproducible and reliable.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: