Related Experiment Video
Updated: Apr 26, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer
Takuro Saito1, Yukinori Kurokawa, Shuji Takiguchi
1Department of Gastroenterological Surgery, Osaka University, Graduate School of Medicine, 2-2-E2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Objectives:
The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions.
Methods:
The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis.
Results:
The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1% based on histological type and 76.6% based on region of lymph node location.
Conclusions:
The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region.
Key Points:
• Multidetector-row computed tomography is widely used to predict pathological nodal status. • An optimal cut-off value of lymph node size has not been determined. • Cut-off values were assessed according to histology and nodal location. • The optimal cut-off values differed based on histology and nodal location. • Diagnostic accuracy was improved by using individual cut-off values for each region.
More Related Videos
07:13Comparison of Predictive Performance of Three Lymph Node Staging Systems in Colorectal Signet Ring Cell Carcinoma Based on Machine Learning Model
Published on: April 18, 2025
05:52Sentinel Lymph Node Mapping and Biopsy for Endometrial Cancer at Early Stage with Laparoscopy
Published on: August 19, 2021