Current densities and total contact currents for 110 and 220kV power line tasks

Leena Korpinen1, Harri Kuisti, Jarmo Elovaara

  • 1Environmental Health, Tampere University of Technology, Tampere, Finland.

Bioelectromagnetics
|August 8, 2014
PubMed

Related Concept Videos

Current Density01:21

Current Density

The total amount of current flowing through one unit value of a cross-sectional area is referred to as current density. If the current flow is uniform, the amount of current flowing through a conductor is the same at all points along the conductor, even if the conductor area varies. The current density consists of the local magnitude and direction of the charge flow, which varies from point to point. Current density is measured in amperes per meter square, and direction is defined as the net...
4.8K
Ampere-Maxwell's Law: Problem-Solving01:17

Ampere-Maxwell's Law: Problem-Solving

A parallel-plate capacitor with capacitance C, whose plates have area A and separation distance d, is connected to a resistor R and a battery of voltage V. The current starts to flow at t = 0. What is the displacement current between the capacitor plates at time t? From the properties of the capacitor, what is the corresponding real current?
To solve the problem, we can use the equations from the analysis of an RC circuit and Maxwell's version of Ampère's law.
For the first part of the...
1.4K
Boundary Conditions for Current Density01:25

Boundary Conditions for Current Density

Current density becomes discontinuous across an interface of materials with different electrical conductivities. The normal component of the current density is continuous across the boundary.
1.4K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
771
Capacitance: Single-Phase And Three-Phase Line01:25

Capacitance: Single-Phase And Three-Phase Line

In electrical power systems, understanding the capacitance of transmission lines is fundamental for efficient operation.
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
846
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
557