First in vivo application and evaluation of a novel method for non-invasive estimation of cardiac output
Theodore G Papaioannou1, Dimitrios Soulis2, Orestis Vardoulis3
1Biomedical Engineering Unit, 1st Dept. of Cardiology, Hippokration Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece; Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Bioengineering, Swiss Federal Institute of Technology, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
Abstract:
Surgical or critically ill patients often require continuous assessment of cardiac output (CO) for diagnostic purposes or for guiding therapeutic interventions. A new method of non-invasive CO estimation has been recently developed, which is based on pressure wave analysis. However, its validity has been examined only in silico. Aim of this study was to evaluate in vivo the reproducibility and accuracy of the "systolic volume balance" method (SVB). Twenty two subjects underwent 2-D transthoracic echocardiography for CO measurement (reference value of CO). The application of SVB method required aortic pressure wave analysis and estimation of total arterial compliance. Aortic pulses were derived by mathematical transformation of radial pressure waves recorded by applanation tonometry. Total compliance was estimated by the "pulse pressure" method. The agreement, association, variability, bias and precision between Doppler and SVB measures of CO were evaluated by intraclass correlation coefficient (ICC), mean difference, SD of differences, percentage error (PR) and Bland-Altman analysis. SVB yielded very reproducible CO estimates (ICC=0.84, mean difference 0.27 ± 0.73 L/min, PR = 16.7%). SVB-derived CO was comparable with Doppler measurements, indicating a good agreement and accuracy (ICC = 0.74, mean difference = -0.22 ± 0.364 L/min, PR ≈ 15). The basic mathematical and physical principles of the SVB method provide highly reproducible and accurate estimates of CO compared with echocardiography.
More Related Videos
08:01Semi-Minimal Invasive Method to Induce Myocardial Infarction in Rats and the Assessment of Cardiac Function by an Isolated Working Heart System
Published on: June 11, 2020
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016