Use of greatly-reduced gas flows in flow-modulated comprehensive two-dimensional gas chromatography-mass spectrometry
Peter Q Tranchida1, Flavio A Franchina1, Paola Dugo2
1Dipartimento di Scienze del Farmaco e dei Prodotti per la Salute, Università di Messina, viale Annunziata, 98168 Messina, Italy.
Abstract:
The present research is specifically based on the use of greatly-reduced gas flows, in flow-modulator (FM) comprehensive two-dimensional gas chromatography systems. In particular, focus of the present research is directed to FM devices characterized by an accumulation stage, and a much briefer re-injection step. It has been widely accepted that the operation of such FM systems requires high gas flows (≥20mL/min), to re-inject the gas-phase contents of sample (or accumulation) loops, onto the second column. On the contrary, it will be herein demonstrated that much lower gas flows (≈ 6-8mL/min) can efficiently perform the modulation step of re-injection. The possibility of using such improved operational conditions is given simply by a fine optimization of the processes of accumulation and re-injection. The application of lower gas flows not only means that second-dimension separations are carried out under better analytical conditions, but, even more importantly, greatly reduces problems which arise when using mass spectrometry (i.e., sensitivity and instrumental pumping capacity).
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
06:51Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...