The assessment of transpulmonary pressure in mechanically ventilated ARDS patients
Davide Chiumello1, Massimo Cressoni, Andrea Colombo
1Dipartimento di Anestesia, Rianimazione (Intensiva e Subintensiva) e Terapia del Dolore, Fondazione IRCCS Ca' Granda-Ospedale Maggiore Policlinico, Via F. Sforza 35, Milan, Italy, chiumello@libero.it.
Purpose:
The optimal method for estimating transpulmonary pressure (i.e. the fraction of the airway pressure transmitted to the lung) has not yet been established.
Methods:
In this study on 44 patients with acute respiratory distress syndrome (ARDS), we computed the end-inspiratory transpulmonary pressure as the change in airway and esophageal pressure from end-inspiration to atmospheric pressure (i.e. release derived) and as the product of the end-inspiratory airway pressure and the ratio of lung to respiratory system elastance (i.e. elastance derived). The end-expiratory transpulmonary pressure was estimated as the product of positive end-expiratory pressure (PEEP) minus the direct measurement of esophageal pressure and by the release method.
Results:
The mean elastance- and release-derived transpulmonary pressure were 14.4 ± 3.7 and 14.4 ± 3.8 cmH₂O at 5 cmH₂O of PEEP and 21.8 ± 5.1 and 21.8 ± 4.9 cmH₂O at 15 cmH₂O of PEEP, respectively (P = 0.32, P = 0.98, respectively), indicating that these parameters were significantly related (r(2) = 0.98, P < 0.001 at 5 cmH₂O of PEEP; r(2) = 0.93, P < 0.001 at 15 cmH₂O of PEEP). The percentage error was 5.6 and 12.0 %, respectively. The mean directly measured and release-derived transpulmonary pressure were -8.0 ± 3.8 and 3.9 ± 0.9 cmH₂O at 5 cmH₂O of PEEP and -1.2 ± 3.2 and 10.6 ± 2.2 cmH₂O at 15 cmH₂O of PEEP, respectively, indicating that these parameters were not related (r(2) = 0.07, P = 0.08 at 5 cmH₂O of PEEP; r (2) = 0.10, P = 0.53 at 15 cmH₂O of PEEP).
Conclusions:
Based on our observations, elastance-derived transpulmonary pressure can be considered to be an adequate surrogate of the release-derived transpulmonary pressure, while the release-derived and directly measured end-expiratory transpulmonary pressure are not related.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...