A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
Published on: May 30, 2016
Two-dimensional structured illumination microscopy
1Bio Imaging Zentrum der Ludwid-Maximilians-Universitt Mnchen, Grohaderner Street 2-4, 82152, Martinsried, Germany.
Abstract:
In widefield fluorescence microscopy, images from all but very flat samples suffer from fluorescence emission from layers above or below the focal plane of the objective lens. Structured illumination microscopy provides an elegant approach to eliminate this unwanted image contribution. To this end a line grid is projected onto the sample and phase images are taken at different positions of the line grid. Using suitable algorithms 'quasi-confocal images' can be derived from a given number of such phase-images. Here, we present an alternative structured illumination microscopy approach, which employs two-dimensional patterns instead of a one-dimensional one. While in one-dimensional structured illumination microscopy the patterns are shifted orthogonally to the pattern orientation, in our two-dimensional approach it is shifted at a single, pattern-dependent angle, yet it already achieves an isotropic power spectral density with this unidirectional shift, which otherwise would require a combination of pattern-shift and -rotation. Moreover, our two-dimensional approach also yields a better signal-to-noise ratio in the evaluated image.
More Related Videos
12:44Super-resolution Imaging of the Cytokinetic Z Ring in Live Bacteria Using Fast 3D-Structured Illumination Microscopy f3D-SIM
Published on: September 29, 2014
14:23Imaging Intermediate Filaments and Microtubules with 2-dimensional Direct Stochastic Optical Reconstruction Microscopy
Published on: March 6, 2018
Related Concept Videos
Two-Dimensional Microscopy in Microbiology
Three-Dimensional Microscopy in Microbiology
Confocal Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...