Related Experiment Video
Updated: Apr 25, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
[A case study regarding the technical and public health feasibility of collecting water from fog]
César A García-Ubaque1, Martha L Vaca-Bohórquez2, Juan C García-Ubaque3
1Facultad Tecnológica, Universidad Distrital Francisco José de Caldas, Bogotá, Colombia, cagarciau@udistrital.edu.co.
Objectives:
Evaluating the collection of water for human consumption from fog nets in San Antonio (Cundinamarca department).
Method:
Water was collected from fog using a prototype 6 m²sensor unit which was installed In the area for 53 days; this water was analysed to assess its quality regarding human consumption.
Results:
The collection area's average daily volume was 43.26 L/day and the parameters evaluated met the minimum values established by local regulations for drinking water (RAS 2000), except for pH.
Conclusion:
This technique represents an alternative for obtaining water fit for human consumption and can be scaled-up to produce the quantity needed for communities living in low rainfall areas. It can thereby lead to improving such populations' health conditions. Its economic feasibility should thus be assessed regarding its implementation and sustainability.
More Related Videos
Related Concept Videos
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Precipitation and Co-precipitation