Detection of copper, lead, cadmium and iron in wine using electronic tongue sensor system

A M Simões da Costa1, I Delgadillo2, A Rudnitskaya1

  • 1CESAM and Chemistry Department, Aveiro University, Campus Universitario de Santiago, Aveiro 3810-193, Portugal.

Talanta
|August 17, 2014
PubMed

Related Concept Videos

Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
801
Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...
88
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
2.2K
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
5.1K