Related Experiment Video
Updated: Apr 25, 2026

Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
Published on: November 9, 2015
Comparison of different types of diffusive gradient in thin film samplers for measurement of dissolved methylmercury
Cristal Fernández-Gómez1, Josep M Bayona1, Sergi Díez1
1Environmental Chemistry Department, Institute of Environmental Assessment and Water Research, IDÆA-CSIC, E-08034 Barcelona, Spain.
Abstract:
Determination of bioavailable concentrations of methylmercury (MeHg(+)) in freshwater is key to further understanding its potential risk and toxicity. In this work, two in-house-manufactured mercury-specific diffusive gradients in thin films (DGT) were used in laboratory to assess the lability of MeHg(+), and to develop a relationship between chemical lability and bioavailability. After diffusing through the diffusive gel, the MeHg(+) accumulated in a thiol functionalised resin gel was extracted using acidic thiourea that was analysed using aqueous-phase propylation followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography (GC) coupled to pyrolysis-atomic fluorescence spectrometry (Py-AFS) detection. The diffusion coefficient (D) at 25°C in agarose (A-DGT) in the absence and presence of dissolved organic matter (DOM) was obtained. Moreover, these values were experimentally compared against polyacrylamide (P-DGT), which is the most frequently used DGT for mercury to date. Statistically significant differences were observed between D values for A-DGT in the absence (3.15×10(-6) cm(2) s(-1)) and presence of DOM (2.68×10(-6) cm(2) s(-1)) and also for P-DGT (2.49×10(-6) and 1.69×10(-6) cm(2) s(-1)). Interestingly, our results show that diffusion of MeHg(+) was higher on agarose diffusive gel with and without DOM in comparison with those observed in polyacrylamide. Even with higher diffusion coefficients of MeHg(+) in the agarose diffusion layer, however, DGT based on polyacrylamide seems to be a better choice for eutrophic waters, when monitoring very low concentrations of MeHg(+), considering its slightly higher uptake capacity.
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...

