Real-time data acquisition and alerts may reduce reaction time and improve perfusionist performance during
1Section of Adult Cardiac Surgery, Department of Clinical Perfusion, New York Presbyterian Hospital, Columbia Campus, New York, NY, USA beckjam@nyp.org.
Abstract:
Delayed perfusionist identification and reaction to abnormal clinical situations has been reported to contribute to increased mortality and morbidity. The use of automated data acquisition and compliance safety alerts has been widely accepted in many industries and its use may improve operator performance. A study was conducted to evaluate the reaction time of perfusionists with and without the use of compliance alert. A compliance alert is a computer-generated pop-up banner on a pump-mounted computer screen to notify the user of clinical parameters outside of a predetermined range. A proctor monitored and recorded the time from an alert until the perfusionist recognized the parameter was outside the desired range. Group one included 10 cases utilizing compliance alerts. Group 2 included 10 cases with the primary perfusionist blinded to the compliance alerts. In Group 1, 97 compliance alerts were identified and, in group two, 86 alerts were identified. The average reaction time in the group using compliance alerts was 3.6 seconds. The average reaction time in the group not using the alerts was nearly ten times longer than the group using computer-assisted, real-time data feedback. Some believe that real-time computer data acquisition and feedback improves perfusionist performance and may allow clinicians to identify and rectify potentially dangerous situations.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiopulmonary Resuscitation IV: Pharmacological Management
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...