Comparison of Tc-99m pertechnetate images with dual-phase Tc 99m MIBI and SPECT images in primary hyperparathyroidism
Sait Sager1, Hojjat Shafipour1, Sertac Asa1
1Department of Nuclear Medicine, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey.
Background:
The purpose of this study was to evaluate the value of Tc-99m pertechnetate planar, dual-phase MIBI and MIBI-SPECT images in the determination and localization of parathyroid lesions.
Materials And Methods:
In this study, 38 patients who underwent operation for primary hyperparathyroidism were included. Tc-99m pertechnetate planar-pinhole imaging of the neck and then MIBI planar and SPECT images in supine position was performed. Late SPECT images were acquired 120 minutes after the injection. Early and late MIBI images were quantitatively evaluated.
Results:
Of the 38 patients, 30 of them had adenoma, 2 patients had hyperplasia and 6 of them were normal on planar images. Thirty-four of 38 patients were positive on SPECT images. SPECT images of the patients with positive results were matched with pathology results.
Conclusion:
As a result, Tc-99m pertechnetate planar-pinhole, Tc-99m MIBI planar and SPECT images are useful for localization of parathyroid lesions especially in multinodular thyroid gland. However, US or CT images are necessary for more accurate localization and Tc-99m pertechnetate images are useful for interpreting and comparing with the early and late MIBI images.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...