Related Experiment Video
Updated: Apr 25, 2026

Rat Model of Right-Sided Cardiac Remodeling and Arrhythmia Using Pulmonary Artery Banding
Published on: August 30, 2024
Personalized surgical repair of left ventricular aneurysm with computer-assisted ventricular engineering
István Hartyánszky1, Attila Tóth2, Balázs Berta2
1Semmelweis University Heart and Vascular Center, Budapest, Hungary drharist@gmail.com.
Objectives:
Although circular ventricular resection techniques are the gold standard of left ventricular (LV) restoration, these techniques can lead to suboptimal results. Postoperative systolic resection can be inadequate, because it must be planned on a heart stopped in diastole. Low cardiac output due to insufficient LV volume results in a potentially unstable condition, and cannot be corrected. Our aim was to find a preoperative method to minimize risk and maximize outcome with ventricular restoration.
Methods:
We created a novel method combining surgery with gadolinium-enhanced magnetic resonance to construct a preoperative 3D systolic heart model. The model was utilized to determine resection points that could be intraoperatively used. According to our calculations with the predetermined resection line, the calculated percentage reduction in LV volume was above 30%, and LV volumes were predicted above normal values; thus, performing the operation using these resection points is likely to be safe and effective. We had a mixed, real-life patient group: mitral insufficiency or pulmonary hypertension were not exclusion criteria.
Results:
Forty-one procedures (12 concomitant mitral valve plasty) were done on consecutive patients in a single-centre experience. The incidence rate of major adverse clinical events was 32% postoperatively (n = 13). Control MRI showed a significant improvement in ejection fraction (18.3 ± 4.3 vs 31.3 ± 3.3; P = 0.04). All patients improved their New York Heart Association (NYHA) class postoperatively (40 patients NYHA III/IV versus 40 NYHA I/II). During long-term follow-up, 1 patient died due to end-stage heart failure.
Conclusions:
Using this model, we were able to find the optimal resection line providing an excellent postoperative result, thus minimizing the risk of low cardiac output syndrome.
More Related Videos
13:10Direct Re-implantation of Left Coronary Artery into the Aorta in Adults with Anomalous Origin of Left Coronary Artery from the Pulmonary Artery ALCAPA
Published on: April 24, 2017
07:24Reduction in Left Ventricular Wall Stress and Improvement in Function in Failing Hearts using Algisyl-LVR
Published on: April 8, 2013
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Aortic Regurgitation III: Medical Management