Related Experiment Video
Updated: Apr 25, 2026

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Myocardial delayed enhancement with dual-source CT: advantages of targeted spatial frequency filtration and image
Yusuke Kurobe1, Kakuya Kitagawa1, Tatsuro Ito1
1Department of Radiology, Mie University School of Medicine, 2-174 Edobashi, Tsu 514-8507, Japan.
Background:
Clinical utility of myocardial delayed-enhancement CT is currently limited because of relatively poor contrast-to-noise ratio (CNR) and artifacts. Targeted spatial-frequency filtration (TSFF) is a hybrid algorithm of half- and full-scan reconstruction that can achieve both high temporal resolution and improved stability of myocardial signal.
Objective:
The purpose of this study was to evaluate image quality of delayed-enhancement CT using TSFF with image averaging and its reproducibility in infarct assessment in comparison with conventional half-scan reconstruction (HALF).
Methods:
Forty patients with suspected coronary artery disease underwent delayed-enhancement CT with HALF and TSFF using dual-source CT. Two blinded readers independently determined the presence and size of delayed enhancement. Image quality, signal-to-noise ratio and CNR were assessed. The presence of delayed enhancement on CT was compared with magnetic resonance imaging in 12 patients.
Results:
TSFF with averaging of 4 image stacks acquired during 1 breathhold demonstrated significantly better image quality compared with HALF. Good left ventricular lumen-myocardium contrast was consistently achieved with TSFF in patients who received iodine dose of >600 mg I/kg. The signal-to-noise ratio and CNR were 11.3 ± 4.2 and 4.5 ± 1.6 by TSFF, being significantly higher than those by HALF (7.9 ± 2.9 and 3.3 ± 1.8; P < .01 for both). Interobserver reproducibility of infarct sizing was markedly improved by using TSFF instead of HALF (intraclass correlation coefficient: 0.86 vs 0.50). Agreement with magnetic resonance imaging by kappa statistics was 0.85 with TSFF and 0.74 with HALF.
Conclusions:
TSFF with image averaging can significantly improve image quality of delayed-enhancement CT and considerably enhances interobserver reproducibility of infarct sizing.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...