Background:
Sternal wires are used to close the thoracic cavity and facilitate healing after median sternotomy (MS). We invented an implantable device that uses these wires as sensors to monitor cardiac electrical activity and tested its utility in collecting electrocardiography (ECG) data in vivo.
Methods:
The wafer-thin silicone device has grooves with embedded metal contacts that secure the sternal wires and connect them to an ECG sensor. We used radiofrequency telemetry to communicate with the implanted device, which was evaluated in three acute swine studies and one chronic-survival swine study. The device was implanted via MS in two acute studies and left thoracotomy in the other. In two acute studies, ECG data were collected with the pigs in four different positions for 2 minutes each; in the third study, we induced ischemia and collected ECG data. For the chronic study, we implanted the device via a left thoracotomy and obtained ECG data weekly until euthanasia on day 27. After each study, the sternum and device were removed and examined.
Results:
The ECG tracings showed distinct P, QRS, and T waveforms with minimal positional or temporal variability. Our device captured signal changes during ischemia before the external control did. In the chronic study, necropsy showed appropriate healing, fibrous encapsulation, and no infection or adverse reactions.
Conclusions:
These initial results showed that our novel device can use sternal wires as electrodes in vivo to monitor cardiac electrical activity and safely capture physiologic signals after surgical placement.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
10:05Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine
Published on: July 7, 2016
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring