Related Experiment Video
Updated: Apr 25, 2026

05:59
An In Vitro Dissolution Determination of Multi-Index Components in Tibetan Medicine Rhodiola Granules
Published on: November 4, 2022
1.8K
Determination of gallic acid with rhodanine by reverse flow injection analysis using simplex optimization.
Wilaiwan Phakthong1, Boonsom Liawruangrath2, Saisunee Liawruangrath3
1Alpha Flow Analysis Group, Department of Chemistry and Center of Excellent for Innovation in Chemistry (PERCH-CIC) Together with Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand.
Talanta
|August 28, 2014
Summary
A new reversed flow injection system accurately determines gallic acid using rhodanine. This method offers high selectivity and precision for analyzing gallic acid in food samples.
Area of Science:
- Analytical Chemistry
- Food Chemistry
- Spectrophotometry
Background:
- Gallic acid is a significant phenolic compound with various health benefits.
- Accurate determination of gallic acid is crucial for quality control in food products.
- Existing methods may lack selectivity or require complex sample preparation.
Purpose of the Study:
- To develop and validate a novel reversed flow injection (rFI) system for gallic acid determination.
- To optimize experimental conditions for enhanced sensitivity and selectivity.
- To assess the method's applicability to real-world samples like longan.
Main Methods:
- Design and construction of a reversed flow injection system.
- Colorimetric detection based on the reaction between gallic acid and rhodanine.
- Optimization of reaction and flow parameters using univariate and multivariate methods.
- Validation of the method's linearity, detection limit, and precision.
- Application to gallic acid determination in longan samples.
Main Results:
- The rFI system achieved gallic acid determination at λmax 520 nm.
- Optimized conditions yielded high selectivity and precision.
- Linearity was observed from 0.1-35.0 mg L⁻¹ with a detection limit of 0.081 mg L⁻¹.
- Relative standard deviations were below 1.96% for various concentrations.
- Successful application to longan samples without interference from other phenolic compounds.
Conclusions:
- The developed rFI method provides a simple, highly selective, and precise approach for gallic acid quantification.
- The method is suitable for routine analysis of gallic acid in complex matrices.
- This technique offers a valuable tool for food quality assessment and research.