Development of a closed-loop J-T cryoablation device with a long cooling area and multiple expansion parts
Cheonkyu Lee1, Seungwhan Baek1, Jisung Lee2
1Cryogenic Engineering Laboratory, Division of Mechanical Engineering, School of Mechanical, Aerospace and Systems Engineering, Korea Advanced Institute of Science and Technology 373-1, Guseong-dong, Yuseong-gu, Daejeon, 305-701, South Korea.
Abstract:
Cryoablation is a surgical procedure used to freeze defective cells by inserting a low temperature probe into a human body to destroy malignant tissues. Miniaturized Joule-Thomson (J-T) refrigerators are often used to minimize the volume of the cooling device and reduce the destruction zone of normal tissue. The cooling effects of the existing probes are not uniformly generated along the longitudinal direction of the probe, which makes their applications less effective in surgeries of incompetent great saphenous veins (GSVs), where the target cells are distributed over a broad range. Long uniform refrigeration is required across the entire area of the probe to apply the same cooling effects. In this paper, a closed-loop J-T cryoablation probe was designed and fabricated to provide uniform refrigeration over a large area, with multiple expansion parts. Using flow boiling heat transfer, uniform cooling of a 200 mm-long and 0.3 mm thickness piece of target tissue was possible and simulated in a gelatin solution. The developed probe produced a greater than 53 K min(-1) cooling rate and the cooling temperature was below 253 K to satisfy the required cell death conditions.
Related Concept Videos
The Joule and Joule–Thomson Experiments
Joule-Thomson Effect
This experiment forces high-pressure gas through a throttle valve or a porous plug to a lower-pressure region. The gas expands as it passes through to...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Mechanisms of Heat Transfer II
Mechanisms of Heat Transfer I
Mechanisms of Heat Transfer
Conduction, accounting for approximately 3% of body heat loss at rest, is the process of exchanging heat between molecules of two materials in direct contact. This can result in both heat loss and gain. For instance, when the body is submerged in water, which conducts heat 20 times more effectively than air, it can either lose or gain significant...