Related Experiment Video
Updated: Apr 25, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Central venous saturation in septic shock: co-oximetry vs gasometry
Carlos M Romero1, Cecilia Luengo1, Eduardo Tobar1
1Unidad de Pacientes Críticos, Departamento de Medicina, Hospital Clínico Universidad de Chile, Santiago Norte, Chile.
Objectives:
Central venous oxygen saturation calculated by gasometry (Gaso-Scvo2) is more available than central venous oxygen saturation measured by co-oximetry (Co-oxy-Scvo2) in environments with less resources and underdeveloped countries. Therefore, we aimed to determine the agreement between Co-oxy-Scvo2 and Gaso-Scvo2 and between central venous oxygen tension measured by gasometry (Gaso-Pcvo2) and Co-oxy-Scvo2, respectively.
Design And Settings:
This is a prospective study in a university hospital's intensive care unit.
Patients:
Sixteen patients were studied during the first 48 hours after diagnosis of septic shock. All patients were intubated, connected to mechanical ventilation, and resuscitated according to the standards of care.
Measurements And Results:
One hundred eleven pairs of central venous blood measurements were analyzed both by conventional gasometry and co-oximetry. Bland and Altman analysis between Co-oxy-Scvo2 and Gaso-Scvo2 showed lack of agreement (1.7 [-10.7, +14.2]). A Gaso-Scvo2 less than 70% had a positive predictive value of 63% in relation to Co-oxy-Scvo2, and its negative predictive value was 90% with 20% false-positives and 5% false-negatives. The area under the receiver operator characteristic curve of Gaso-Pcvo2 to discriminate a Co-oxy-Scvo2 greater than or equal to 70% was 0.87 (confidence interval, 0.80-0.93), and the best cut-off point was a Gaso-Pcvo2 more than 40 mm Hg, (sensitivity, 75%; specificity, 93%).
Conclusions:
The reliability of Gaso-Scvo2 determination during the resuscitation phase of septic shock is not acceptable. There is a good agreement between a Gaso-Pcvo2 more than 40 mm Hg and a Co-oxy-Scvo2 greater than or equal to 70%. Our results suggest that given these limitations, Gaso-Scvo2 results should be interpreted with caution, helped by Gaso-Pcvo2 measurements and in context with other perfusion parameters.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood