Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Validity and applicability of a new recording method for hypertension
Minerva Mas-Heredia1, Eloisa Molés-Moliner1, Luis González-de Paz2
1Centro de Salud Les Corts, Consorci d'Atenció Primària de Salut Eixample (CAPSE), Barcelona, Spain.
Introduction And Objectives:
Blood pressure measurement methods and conditions are determinants of hypertension diagnosis. A recent British guideline recommends systematic 24-h ambulatory blood pressure monitoring. However, these devices are not available at all health centers and they can only be used by 1 patient per day. The aim of this study was to test a new blood pressure recording method to see if it gave the same diagnostic results as 24-h blood pressure monitoring.
Methods:
One-hour blood pressure monitoring under routine clinical practice conditions was compared with standard method of day time recording by analyzing the coefficient of correlation and Bland-Altman plots. The Kappa index was used to calculate degree of agreement. Method sensitivity and specificity were also analyzed.
Results:
Of the 102 participants, 89 (87.3%) obtained the same diagnosis regardless of method, with high between-method agreement (κ= 0.81; 95% confidence interval, 0.71-0.91). We observed robust correlations between diastolic (r=0.85) and systolic blood pressure (r=0.76) readings. Sensitivity and specificity for the new method for diagnosing white coat hypertension were 85.2% (95% confidence interval 67.5%-94.1%) and 92% (95% confidence interval, 83.6%-96.3%), respectively.
Conclusions:
One-hour blood pressure monitoring is a valid and reliable method for diagnosing hypertension and for classifying hypertension subpopulations, especially in white coat hypertension and refractory hypertension. This also leads to a more productive use of monitoring instruments.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: