Related Experiment Video
Updated: Apr 24, 2026

Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry
Published on: February 4, 2017
Initial Evaluation of (99m)Tc(CO)3(ASMA) as a Renal Tracer in Healthy Human Volunteers
Malgorzata Lipowska1, Jeffrey Klenc1, Russell D Folks1
1Department of Radiology and Imaging Sciences, Emory University, 1364 Clifton Road, NE, Atlanta, GA 30322 USA.
Purpose:
Preclinical studies in rats showed that two of (99m)Tc(CO)3(ASMA) isomers (rac- and L-ASMA) had pharmacokinetic properties equivalent to that of (131)I-OIH, the radiopharmaceutical standard for the measurement of effective renal plasma flow. The aim of this study was to evaluate the pharmacokinetics of (99m)Tc(CO)3(ASMA) isomers in healthy human subjects.
Methods:
Three ASMA ligands (rac-, L- and D-ASMA) were labeled with (99m)Tc(CO)3 using an IsoLink kit (Covidien), and each formed (99m)Tc(CO)3(ASMA) tracer was co-injected with (131)I-OIH into healthy human subjects followed by sequential imaging, plasma clearance measurements and timed urine collection. Plasma protein binding, red cell uptake and percent injected dose in the urine were determined. Urine from each group of volunteers was analyzed for metabolites by HPLC.
Results:
Image quality was excellent with all three agents. Each (99m)Tc(CO)3(ASMA) preparation was excreted unchanged in the urine. The plasma clearance ratio ((99m)Tc(CO)3(ASMA)/(131)I-OIH) was 81 ± 3 % for D-ASMA compared to only 20 ± 4 % for L-ASMA and 37 ± 7 % for rac-ASMA; the 81 % clearance ratio for D-ASMA isomer is still ∼ 30 % higher than the (99m)Tc-MAG3/(131)I-OIH clearance ratio (∼50-60 %). Red cell uptake was similar for all three tracers (6-9 %), and all tracers had a relatively rapid renal excretion; at 3 h, the (99m)Tc(CO)3(ASMA)/(131)I-OIH urine ratio was 100 ± 3 % for D-ASMA, 80 ± 2 % for L-ASMA and 88 ± 1 % for rac-ASMA.
Conclusions:
The renal excretion characteristics of (99m)Tc(CO)3(D-ASMA) in humans are superior to those of the other two (99m)Tc(CO)3(ASMA) isomers studied, but are still inferior to (131)I-OIH, even though there was no difference in the clearance of two of (99m)Tc(CO)3(ASMA) isomers and (131)I-OIH in rats. The work described here demonstrates the sensitivity in in vivo biological behavior of (99m)Tc(CO)3(ASMA) isomers to their subtle structural differences.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies IV: Magnetic Resonance Imaging