Developmental validation of the PowerPlex(®) ESI 16/17 Fast and PowerPlex(®) ESX 16/17 Fast Systems
Robert S McLaren1, Jeanne Bourdeau-Heller1, Jaynish Patel1
1Promega Corporation, Madison, WI 53711-5399, USA.
Forensic Science International. Genetics
|September 3, 2014
Summary
New PowerPlex® ESI and ESX Fast Systems offer rapid DNA amplification from various sample types, including direct amplification from swabs and FTA cards. These validated systems ensure concordance and sensitivity for forensic DNA analysis.
Area of Science:
- Forensic Science
- Molecular Biology
- Genetics
Background:
- The PowerPlex® ESI and ESX Systems were developed in 2009 to meet European forensic group requirements for STR multiplexes.
- Faster cycling versions were developed to improve efficiency in DNA analysis.
Purpose of the Study:
- To perform developmental validation of the new PowerPlex® ESI Fast and ESX Fast Systems.
- To assess their performance for direct amplification and compatibility with various sample types and platforms.
Main Methods:
- Developmental validation following SWGDAM and DAB guidelines.
- Testing direct amplification from blood and buccal samples on FTA and non-FTA paper, and SwabSolution™ extracts.
- Assessing concordance with original PowerPlex® ESI and ESX Systems.
Main Results:
- No changes in autosomal primer pair sequences, showing full concordance with original systems.
- Sensitive detection of low DNA levels and robust profiles from high input DNA.
- Tolerance to PCR inhibitors and variations in reaction components.
- Compatibility with multiple thermal cyclers and capillary electrophoresis platforms.
Conclusions:
- The PowerPlex® ESI Fast and ESX Fast Systems are validated for forensic DNA analysis.
- These systems offer rapid, sensitive, and robust DNA profiling from diverse sample types.
- Their compatibility with various equipment enhances their utility in forensic laboratories.
Related Concept Videos
Fast Decoupled and DC Powerflow
951
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
951
Power Factor Correction
798
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
798
Electrical Power
3.0K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.0K
Multimachine Stability
677
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
677
The Power Flow Problem and Solution
1.2K
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the power...
1.2K
Power Factor
1.0K
The power factor is defined as the ratio of average (or active) power to apparent power, as illustrated by the relation
1.0K


