Nasal CPAP (Infant Flow) applied at birth in extremely low birth weight newborns
Agnieszka Nowicka, Ryszard Lauterbach1
1Klinika Neonatologii UJ CM, Kopernika 23, 31-501 Kraków, ryszard@lauterbach.pl.
Objective:
Evaluation of nasal CPAP (Infant Flow) as a ventilatory support, applied at birth in spontaneously breathing, extremely low birth weight newborns (ELBW).
Material And Methods:
Retrospective analysis of the clinical course of respiratory distress syndrome (RDS) in 97 ELBW, who needed ventilatory support. In all patients the noninvasive ventilatory support was introduced within the first minute of life.
Results:
Among all analyzed newborns, 37.1% of patients were not intubated during hospitalization. Moreover, another 10.3% patients were intubated only due to surfactant administration according to the INSURE method and after 2-3 minutes of invasive ventilation they were switched to n-CPAP. Nearly half (47.4%) of all evaluated ELBW newborns who needed ventilatory support avoided mechanical ventilation. We found the frequency of bronchopulmonary dysplasia in 97 analyzed patients markedly lower when compared to data presented in literature (19% vs 34%; p=0.026).
Conclusion:
We suggest that starting ventilatory support with the n-CPAP from the first minute of life is a safe and effective strategy in extremely low birth weight infants. It also reduces the costs of treatment, associated with surfactant administration.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Suctioning the Nasopharyngeal Airway
Equipment Required
Sleep Apnea
The condition is more prevalent among...