Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Blood pressure variability in patients with atrial fibrillation
Valentina D A Corino1, Federico Lombardi2, Luca T Mainardi1
1Dipartimento di Elettronica, Informatica e Bioingegneria, Politecnico di Milano, via Golgi 32, 20133 Milan, Italy.
Abstract:
The highly irregular ventricular rate during atrial fibrillation (AF) represents a unique and physiological experimental model to eliminate the influence of rhythmical components of RR variability on arterial pressure variability for investigating the origin of low frequency (LF) component in arterial pressure. Surface ECG, blood pressure and respiratory signals were recorded in thirty patients with persistent AF, at rest and during a passive orthostatic stimulus ("tilt test"). Short-term systolic (SAP) and diastolic arterial pressure (DAP) variability was estimated by autoregressive method. In 15 patients (group A), SAP significantly increased during tilt (from 98±16 to 114±18mmHg, p<0.001 rest vs. tilt), whereas in the remaining patients (group B) SAP remained almost unchanged (from 108±16 to 104±17mmHg, p=0.05, rest vs. tilt). No clinical differences were found between group A and B. When analyzing group A, a significant increase in the LF power in SAP and DAP variability was observed during tilt (SAP: 2.24±2.75 vs. 6.60±5.11mmHg(2), p<0.05, rest vs. tilt; DAP: 3.54±1.95 vs. 4.38±3.21mmHg(2), p<0.05, rest vs. tilt). No significant differences were found in group B. In AF patients, changes of arterial pressure variability during tilt were not uniform. Vascular regulatory mechanisms appeared to be still efficient only in the subgroup of patients who responded to a sympathetic stimulus with an increased SAP. In these subjects tilt increased the LF component in arterial pressure variability, thus mimicking the physiological response observed in subjects with sinus rhythm.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Factors affecting Blood pressure
Physiological Factors: