Related Experiment Video
Updated: Apr 24, 2026

Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing
Published on: May 8, 2021
Urinary dipstick proteinuria testing: does automated strip analysis offer an advantage over visual testing?
Dane A De Silva1, Anne C Halstead2, Anne-Marie Côté3
1Department of Pathology and Laboratory Medicine, Children's and Women's Health Centre of British Columbia and the University of British Columbia, Vancouver BC; Department of Obstetrics and Gynaecology, University of British Columbia, Vancouver BC.
Automated and visual urine dipstick tests show similar, low sensitivity for detecting proteinuria (protein:creatinine ratio ≥ 30 mg/mmol) in pregnant women. Neither method is superior for screening in outpatient settings.
Area of Science:
- Clinical Chemistry
- Maternal Health
- Diagnostic Accuracy
Background:
- Proteinuria is a key indicator of preeclampsia in pregnancy.
- Accurate and timely screening for proteinuria is crucial for maternal and fetal outcomes.
- Urine dipstick tests are commonly used for proteinuria screening, with both visual and automated reading methods available.
Purpose of the Study:
- To compare the diagnostic performance of automated versus visually read urine dipstick tests.
- To evaluate the detection of a random protein:creatinine ratio (PrCr) ≥ 30 mg/mmol.
- To assess screening accuracy in pregnant women in a high-risk maternity clinic setting.
Main Methods:
- Prospective collection of urine samples from 160 pregnant women.
- Division of samples into aliquots for visual and automated dipstick testing.
- Comparison of dipstick results (proteinuria ≥ 1+) against a reference standard of PrCr ≥ 30 mg/mmol using non-dilute samples.
Main Results:
- Both visual and automated dipstick tests demonstrated low sensitivity (56.0% and 53.8%, respectively).
- Positive likelihood ratios were 15.0 (visual) and 24.6 (automated).
- Negative likelihood ratios were 0.46 (visual) and 0.47 (automated).
Conclusions:
- Automated dipstick testing offers no significant advantage over visual testing for proteinuria detection in this pregnant cohort.
- The sensitivity of dipstick tests may be influenced by the specific test strips and automated readers used.
- Further research is needed to optimize dipstick performance for proteinuria screening in pregnancy.
More Related Videos
Related Concept Videos
Urine Studies I: Urinalysis
Automated Microbial Diagnostics