Background:
Small solute clearance, especially that derived from residual renal function (RRF), is an independent risk factor for death in peritoneal dialysis (PD) patients. Assessment of solute clearance is time-consuming and prone to multiple errors. Cystatin C is a small protein which has been used as a glomerular filtration rate (GFR) marker. We investigated whether serum cystatin C concentrations are related to mortality in patients receiving PD. ♦
Methods:
New and prevalent PD patients (n = 235) underwent assessment of Kt/Vurea, RRF, weekly creatinine clearance (CCr), normalized protein catabolic rate (nPCR) and a peritoneal equilibration test (PET) at intervals. Blood was collected simultaneously for cystatin C measurement. Patients were followed for a median of 1,429 days (range 12 to 2,964 days) until death or study closure. Cause of death was recorded where given. Cox regression was performed to determine whether cystatin C had prognostic value either independently or with adjustment for other factors (age, sex, dialysis modality, diabetic status, cardiovascular comorbidity, Kt/V, CCr, RRF, nPCR or 4 h dialysate to plasma creatinine ratio (4 h D/Pcr) during the PET). The primary outcomes were all-cause mortality and treatment failure. ♦
Results:
There were 93 deaths. Increasing age and 4 h D/Pcr ratio, decreased RRF and presence of diabetes were significantly [p < 0.05] negatively associated with survival and treatment failure. Serum cystatin C was not related to either outcome. ♦
Conclusions:
Serum cystatin C concentration does not predict mortality or treatment failure in patients receiving PD.
More Related Videos
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Chronic Kidney Disease III: Interprofessional Care
Serum Studies: Renal Function Tests
Peritoneal Dialysis III: Nursing Management
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...