Accuracy of fluorodeoxyglucose-PET imaging for differentiating benign from malignant pleural effusions: a
José M Porcel1, Paula Hernández1, Montserrat Martínez-Alonso2
1Pleural Diseases Unit, Departments of Internal Medicine Arnau de Vilanova University Hospital, Biomedical Research Institute of Lleida, Lleida, Spain.
Background:
The role of fluorodeoxyglucose (FDG)-PET imaging for diagnosing malignant pleural effusions is not well defined. The aim of this study was to summarize the evidence for its use in ruling in or out the malignant origin of a pleural effusion or thickening.
Methods:
A meta-analysis was conducted of diagnostic accuracy studies published in the Cochrane Library, PubMed, and Embase (inception to June 2013) without language restrictions. Two investigators selected studies that had evaluated the performance of FDG-PET imaging in patients with pleural effusions or thickening, using pleural cytopathology or histopathology as the reference standard for malignancy. Subgroup analyses were conducted according to FDG-PET imaging interpretation (qualitative or semiquantitative), PET imaging equipment (PET vs integrated PET-CT imaging), and/or target population (known lung cancer or malignant pleural mesothelioma). Study quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2. We used a bivariate random-effects model for the analysis and pooling of diagnostic performance measures across studies.
Results:
Fourteen non-high risk of bias studies, comprising 407 patients with malignant and 232 with benign pleural conditions, met the inclusion criteria. Semiquantitative PET imaging readings had a significantly lower sensitivity for diagnosing malignant effusions than visual assessments (82% vs 91%; P = .026). The pooled test characteristics of integrated PET-CT imaging systems using semiquantitative interpretations for identifying malignant effusions were: sensitivity, 81%; specificity, 74%; positive likelihood ratio (LR), 3.22; negative LR, 0.26; and area under the curve, 0.838. Resultant data were heterogeneous, and spectrum bias should be considered when appraising FDG-PET imaging operating characteristics.
Conclusions:
The moderate accuracy of PET-CT imaging using semiquantitative readings precludes its routine recommendation for discriminating malignant from benign pleural effusions.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Pleural Effusion II: Symptoms and Management
A pleural effusion is the abnormal collection of fluid between the parietal and visceral pleura layers of tissue that form the lining of the lungs and chest cavity. It can occur independently or due to surrounding parenchymal diseases, such as infection, malignancy, or inflammatory conditions.
Clinical Manifestations:
