Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Analysis of human breath samples using a modified thermal desorption: gas chromatography electrospray ionization
James C Reynolds1, Modupe A Jimoh, Cristina Guallar-Hoyas
1Centre for Analytical Science, Department of Chemistry, Loughborough University, Ashby Road, Loughborough LE11 3TU, UK.
Abstract:
A two-stage thermal desorption/secondary electrospray ionization/time-of-flight mass spectrometry for faster targeted breath profiling has been studied. A new secondary electrospray ionization (SESI) source was devised to constrain the thermal desorption plume and promote efficient mixing in the ionization region. Further, a chromatographic pre-separation stage was introduced to suppress interferences from siloxanes associated with thermal desorption profiles of exhaled breath samples.In vitro tests with 5-nonanone indicated an increased sensitivity and a lowered limit-of-detection, both by a factor of ~4, the latter to an on-trap mass of 14.3 ng, equivalent to a sampled breath concentration of 967 pptv. Analysis of the mass spectrometric responses from 20 breath samples acquired sequentially from a single participant indicated enhanced reproducibility (reduced relative standard deviations (RSD) for 5-nonanone, benzaldehyde and 2-butanone were 28 %, 16% and 14% respectively. The corresponding values for an open SESI source were that 5-nonanone was not detected, with %RSD of 39% for benzaldehyde and 31% for 2-butanone).The constrained source with chromatographic pre-separation resulted in an increase in the number of detectable volatile organic compounds (VOCs) from 260 mass spectral peaks with an open SESI source to 541 peaks with the constrained source with pre-separation. Most of the observed VOCs were present at trace levels, at less than 2.5% of the intensity of the base peak.Seventeen 2.5 dm(3) distal breath samples were collected from asthma patients and healthy controls respectively, and subjected to comparative high-throughput screening using thermal desorption/SESI/time-of-flight mass spectrometry (TD-SESI-ToFMS). Breath metabolites were detected by using a background siloxane ion (hexamethylcyclotrisiloxane m/z 223.0642) as an internal lockmass. Eleven breath metabolites were selected from the breath research literature and successfully targeted. These data reinforce the proposition that TD-SESI-MS has potential for development as a rapid screening method for disease stratification and targeted metabolism profiling.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...