Related Experiment Video
Updated: Mar 3, 2026

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Predicting Risk in Transcatheter Aortic Valve Implantation: Comparative Analysis of EuroSCORE II and Established Risk
Miriam Silaschi1, Lenard Conradi1, Moritz Seiffert2
1Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany.
Background:
The logistic European System for Cardiac Operative Risk Evaluation (logEuroSCORE) II was developed to improve prediction of mortality in cardiac surgery. However, no specific tools are available for risk prediction in transcatheter aortic valve implantation (TAVI). The recently introduced EuroSCORE II was compared with established risk scores.
Patients And Methods:
We assessed 457 consecutive patients (80.5 ± 7.1 years, 52.3% female) undergoing TAVI. Preoperative risk evaluation included logEuroSCORE I, EuroSCORE II, Society of Thoracic Surgeons (STS), Ambler, and Parsonnet scores. Validity was assessed by receiver-operating characteristic (ROC) and area under the curve (AUC).
Results:
A 30-day mortality was 9.6% (44/457). Calculated scores were logEuroSCORE I 22.0%, confidence interval (CI) 21.0 to 24.6; EuroSCORE II 7.0%, CI 6.4 to 8.1; STS 7.9%, CI 7.7 to 9.5; Ambler score 6.9%, CI 5.7 to 7.0; and Parsonnet score 23.8%, CI 20.9 to 24.1. ROC analyses demonstrated no predictive value: logEuroSCORE I AUC 0.56, CI 0.47 to 0.65; EuroSCORE II AUC 0.54, CI 0.46 to 0.63; STS AUC 0.57, CI 0.49 to 0.66; Ambler AUC 0.52, CI 0.43 to 0.60; and Parsonnet AUC 0.51, CI 0.43 to 0.60. Accuracy and thresholds were measured on behalf of Youden index. Accuracy ranged between 44.2% (Parsonnet) and 66.3% (logEuroSCORE I). Thresholds were logEuroSCORE I 26%, EuroSCORE II 7%, STS 6%, Ambler 3%, and Parsonnet 19%.
Conclusions:
No risk evaluation system provided acceptable predictive ability. Scores derived from conventional cardiac surgery failed in risk prediction for TAVI. Specific risk tools are required. Until available, estimation of risk has to rely on judgment of an interdisciplinary heart team regarding individual patient factors.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT