Related Experiment Video
Updated: Apr 24, 2026

Reduced Complications after Arterial Reconnection in a Rat Model of Orthotopic Liver Transplantation
Published on: November 7, 2020
Graft Patency in Long-term Survivors after Renovisceral Debranching with VORTEC
Anna Winklehner1, Thi Dan Linh Nguyen-Kim, Thomas Pfammatter
1Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland, anna.winklehner@usz.ch.
Purpose:
This study was designed to evaluate retrospectively the long-term stent-graft patency after renovisceral revascularization with Viabahn Open Revascularization Technique (VORTEC) using computed tomography angiography (CTA) and magnetic resonance angiography (MRA).
Methods:
In 34 patients (seven women; mean age 72 ± 8 years) with aortic aneurysm, 63 renovisceral vessels (i.e., 54 renal, nine visceral arteries) were revascularized with VORTEC between 2004 and 2009. All patients obtained a pre- and postinterventional CTA and at least one follow-up CTA or MRA after 6 or more months following intervention (median follow up: 43 months). Detection of bypass occlusion, bypass stenosis, infolding, stent-graft fractures and dislocations, and kidney shrinkage were noted by two readers in consensus. Furthermore, mortality during follow-up was assessed using the medical report.
Results:
During follow-up, 12.6 % of stent-grafts occluded. Cumulative patency rate was 95.2 ± 2.7 % at 12 months, 87.7 ± 4.4 % at 24 and 36 months, and 84.7 ± 5.2 % at 48, 60, 72, 84, and 89 months, respectively. Overall, 19 % of stent-grafts (12/63) developed bypass stenosis (<50 %, 10 stent-grafts; > 50 %, 2 stent-grafts), in one case stenosis (>70 %) was suspected to be hemodynamically significant. No secondary dislocation, no infolding of renovisceral stent-grafts, and no stent-graft fracture occurred. Kidney shrinkage occurred in nine patients, primarily in patients with an occluded Viabahn (n = 7). Eleven patients (32.3 %) died within the follow-up time period.
Conclusions:
In long-term survivors after VORTEC cumulative patency rate remained high, and no stent-graft fractures or secondary dislocations occurred.